Shell Nederland Chemie – Cation Water Vessel, Moerdijk

Project Overview

The Shell Nederland Chemie project at Moerdijk in the Netherlands involved the full interior coating removal of Cation Water Vessel V-402B, a 6.4 metre high vessel with a 3.5 metre diameter located within an active chemical processing facility. The work was carried out between 19 and 30 October 2016 by RPR operators from Bilfinger Salamis UK, under the supervision of RPR Technologies, and in coordination with Bilfinger Brabant Mobiel and Shell Nederland Chemie site management.

This was the first time RPR heat induction technology had been trialled at a Shell Nederland Chemie facility, and the project presented a unique set of circumstances that required careful planning and close collaboration between all parties before work could commence. Navigating Shell’s strict electrical safety protocols, confined space entry permits, and site access requirements was a significant undertaking in itself, but once cleared, the RPR Induction Disbonder proved highly effective on what turned out to be a far more complex coating system than initially anticipated.

The vessel originally appeared to have a simple 300 micron glass flake interior coating. Upon entry and inspection, the actual coating was found to be approximately 10 times thicker than specified, comprising multiple distinct coating systems across different zones of the vessel interior:

  • The tank shell carried a two-layer coating of approximately 2.5 to 3mm of ebonite topped with 0.5mm of glass flake
  • The lower dome featured a soft rubber coating of approximately 6mm glued directly to the steel substrate
  • The interface zone between the shell and the lower dome had a four-layer coating totalling approximately 12mm in thickness, comprising ebonite, two layers of unknown intermediate materials, and a final soft rubber layer

This discovery extended the project from a planned one-week duration to two weeks, but the RPR Induction Disbonder handled all coating types successfully, delivering a result that satisfied Shell Nederland Chemie’s requirements and prompted the client to pursue a standardised working procedure for this type of application going forward.

Services Included

RPR Technologies delivered a full confined space interior coating removal service inside Cation Water Vessel V-402B at Shell Nederland Chemie’s Moerdijk facility, working under Shell’s strict safety and environmental standards within an active chemical processing plant.

Equipment and system setup:

  • RPR GreenTank Induction Disbonder deployed inside the vessel using a complete self-contained system setup
  • System components including the induction disbonder unit, water deposit, diesel generator, and water cooler mounted on a trailer outside the vessel
  • Additional utilities including an exhaust fan and isolation transformer used to maintain safe atmospheric and electrical conditions inside the confined space throughout the operation
  • Two RPR operators from Bilfinger Salamis UK working inside the vessel under direct supervision of RPR Technologies supervisors

Coating types successfully removed:

  • Ebonite topped with glass flake across the tank shell (2.5 to 3mm ebonite, 0.5mm glass flake)
  • Soft rubber coating approximately 6mm thick glued directly to the steel substrate on the lower dome
  • Four-layer composite coating up to 12mm thick at the interface zone between the shell and lower dome, comprising ebonite, two layers of unknown intermediate materials, and a final soft rubber layer

Removal process and outcomes:

  • The induction process thermally disbonded each coating layer from the steel substrate, releasing it as solid flakes that could be scraped and collected without generating dust, airborne particles, or the need for any abrasive media
  • Ideal removal rate of approximately 3m2 per hour achieved, with a real-world rate of 1.5m2 per hour inclusive of evacuation of removed material
  • Entire interior coating successfully removed across all zones despite the unexpectedly thick and multi-layered coating system and numerous obstructions in the bottom of the vessel restricting access and movement
  • Only a sweep blast subsequently required to achieve the specified surface cleanliness and profile for the new coating application
  • Total grit consumption for the full project: zero kilograms, compared to the 90,000 to 150,000 kilograms that would have been required using traditional sandblasting or UHP methods
  • Total energy consumption for the full scope of work: approximately 525kWh

Conclusion

The Shell Nederland Chemie Moerdijk project stands as one of the most technically demanding confined space coating removal projects in RPR’s case study portfolio, and the results delivered across every key measure confirmed the capability of RPR induction technology in the most challenging of chemical vessel environments. The outcomes achieved tell a compelling story:

  • Zero kilograms of grit waste produced across the full project, compared to an estimated 90,000 to 150,000 kilograms using traditional sandblasting or UHP methods
  • Maximum coating thickness of 12mm successfully removed, across a vessel that initially appeared to require only 300 micron glass flake removal
  • Multiple distinct coating types including ebonite, glass flake, soft rubber linings, and unknown intermediate layers all handled effectively by the RPR Induction Disbonder
  • Confined space safety maintained throughout, with no dust, no airborne particles, and no abrasive media required inside the vessel at any point
  • Only a sweep blast required after RPR removal to achieve the specified surface profile for recoating, demonstrating the quality of the surface left behind
  • Result rated as very satisfactory by Shell Nederland Chemie

Beyond the technical performance, this project demonstrated the ability of RPR heat induction technology to operate safely and effectively within the strict electrical safety protocols, confined space entry requirements, and environmental standards of an active Shell chemical processing facility. In an environment where grit blasting was completely ruled out and contamination risks were particularly high, RPR delivered the only viable solution available.

The success of the Moerdijk project directly prompted Shell Nederland Chemie to express their intention to establish a standardised working procedure for RPR induction coating removal on future vessel projects at the facility, a clear endorsement of the technology’s performance and its suitability for ongoing application in chemically sensitive confined space environments.

Project Overview

The Shell Nederland Chemie project at Moerdijk in the Netherlands involved the full interior coating removal of Cation Water Vessel V-402B, a 6.4 metre high vessel with a 3.5 metre diameter located within an active chemical processing facility. The work was carried out between 19 and 30 October 2016 by RPR operators from Bilfinger Salamis UK, under the supervision of RPR Technologies, and in coordination with Bilfinger Brabant Mobiel and Shell Nederland Chemie site management.

This was the first time RPR heat induction technology had been trialled at a Shell Nederland Chemie facility, and the project presented a unique set of circumstances that required careful planning and close collaboration between all parties before work could commence. Navigating Shell’s strict electrical safety protocols, confined space entry permits, and site access requirements was a significant undertaking in itself, but once cleared, the RPR Induction Disbonder proved highly effective on what turned out to be a far more complex coating system than initially anticipated.

The vessel originally appeared to have a simple 300 micron glass flake interior coating. Upon entry and inspection, the actual coating was found to be approximately 10 times thicker than specified, comprising multiple distinct coating systems across different zones of the vessel interior:

  • The tank shell carried a two-layer coating of approximately 2.5 to 3mm of ebonite topped with 0.5mm of glass flake
  • The lower dome featured a soft rubber coating of approximately 6mm glued directly to the steel substrate
  • The interface zone between the shell and the lower dome had a four-layer coating totalling approximately 12mm in thickness, comprising ebonite, two layers of unknown intermediate materials, and a final soft rubber layer

This discovery extended the project from a planned one-week duration to two weeks, but the RPR Induction Disbonder handled all coating types successfully, delivering a result that satisfied Shell Nederland Chemie’s requirements and prompted the client to pursue a standardised working procedure for this type of application going forward.

Services Included

RPR Technologies delivered a full confined space interior coating removal service inside Cation Water Vessel V-402B at Shell Nederland Chemie’s Moerdijk facility, working under Shell’s strict safety and environmental standards within an active chemical processing plant.

Equipment and system setup:

  • RPR GreenTank Induction Disbonder deployed inside the vessel using a complete self-contained system setup
  • System components including the induction disbonder unit, water deposit, diesel generator, and water cooler mounted on a trailer outside the vessel
  • Additional utilities including an exhaust fan and isolation transformer used to maintain safe atmospheric and electrical conditions inside the confined space throughout the operation
  • Two RPR operators from Bilfinger Salamis UK working inside the vessel under direct supervision of RPR Technologies supervisors

Coating types successfully removed:

  • Ebonite topped with glass flake across the tank shell (2.5 to 3mm ebonite, 0.5mm glass flake)
  • Soft rubber coating approximately 6mm thick glued directly to the steel substrate on the lower dome
  • Four-layer composite coating up to 12mm thick at the interface zone between the shell and lower dome, comprising ebonite, two layers of unknown intermediate materials, and a final soft rubber layer

Removal process and outcomes:

  • The induction process thermally disbonded each coating layer from the steel substrate, releasing it as solid flakes that could be scraped and collected without generating dust, airborne particles, or the need for any abrasive media
  • Ideal removal rate of approximately 3m2 per hour achieved, with a real-world rate of 1.5m2 per hour inclusive of evacuation of removed material
  • Entire interior coating successfully removed across all zones despite the unexpectedly thick and multi-layered coating system and numerous obstructions in the bottom of the vessel restricting access and movement
  • Only a sweep blast subsequently required to achieve the specified surface cleanliness and profile for the new coating application
  • Total grit consumption for the full project: zero kilograms, compared to the 90,000 to 150,000 kilograms that would have been required using traditional sandblasting or UHP methods
  • Total energy consumption for the full scope of work: approximately 525kWh

Conclusion

The Shell Nederland Chemie Moerdijk project stands as one of the most technically demanding confined space coating removal projects in RPR’s case study portfolio, and the results delivered across every key measure confirmed the capability of RPR induction technology in the most challenging of chemical vessel environments. The outcomes achieved tell a compelling story:

  • Zero kilograms of grit waste produced across the full project, compared to an estimated 90,000 to 150,000 kilograms using traditional sandblasting or UHP methods
  • Maximum coating thickness of 12mm successfully removed, across a vessel that initially appeared to require only 300 micron glass flake removal
  • Multiple distinct coating types including ebonite, glass flake, soft rubber linings, and unknown intermediate layers all handled effectively by the RPR Induction Disbonder
  • Confined space safety maintained throughout, with no dust, no airborne particles, and no abrasive media required inside the vessel at any point
  • Only a sweep blast required after RPR removal to achieve the specified surface profile for recoating, demonstrating the quality of the surface left behind
  • Result rated as very satisfactory by Shell Nederland Chemie

Beyond the technical performance, this project demonstrated the ability of RPR heat induction technology to operate safely and effectively within the strict electrical safety protocols, confined space entry requirements, and environmental standards of an active Shell chemical processing facility. In an environment where grit blasting was completely ruled out and contamination risks were particularly high, RPR delivered the only viable solution available.

The success of the Moerdijk project directly prompted Shell Nederland Chemie to express their intention to establish a standardised working procedure for RPR induction coating removal on future vessel projects at the facility, a clear endorsement of the technology’s performance and its suitability for ongoing application in chemically sensitive confined space environments.

Share:

Explore innovation, technology and news from our journey

Explore the latest innovations, project stories, and insights from the ACR Tech team.